国产精品毛片网站_久久九九性爱视频_怡红院最新网址_欧美黄页网站在线_午夜性爽快下面出水了_日本欧美亚洲二区_国产成人精品日本亚洲直播一_亚洲国产日韩欧美大陆综合_在线观看不卡的无码av_无码成人影院在线观看

Welcome to visit Kunshan Guangxinqi!
Tel:0512-87882886 Message Sitemap 中文版 EN

通用banner
Current position : Home >> News >> Technical information

Air shower room design points

2019-06-26

There are two kinds of expressions in the air shower room, such as excellent shower and cargo shower. The choice of air shower room for people is generally based on 25 people. The general number is less than 25 people and chooses single air shower room. 25 people or more and 50 people or less. Choose a double air shower, and so on. The cargo shower room is a device that cleans some goods. It has no bottom plate and the size is determined by the size of the car that loads and unloads the goods. This kind of equipment installation is convenient and optional, and it is a future development trend.


Air shower room design data reference: 1, air shower room structure layout standard rope: column and column, column and shear wall between the frame beam, the frame beam surrounded by the plate with cast-in-place hollow plate. 2. The air shower chamber frame beam is generally a dark beam, and the height of the dark beam is the same as the thickness of the hollow plate. 3. The main structure of the air shower chamber can be designed according to the current standard, and the dark beam is considered by the wide flat beam. 4. The cast-in-place hollow slab is normally calculated by one-way or two-way force to stop the internal force reinforcement.


Air shower room design room plan common structural requirements: 1. Calculate the cast-in-place hollow slab is a new type of structural system with the development of BDF technology and BDF thin-walled pipe data. When designing and calculating the air shower room, Refer to the calculation method of the solid steel slab or the beamless floor to stop the calculation of the internal force reinforcement. When calculating the reinforcement, the direction of the parallel pipe can be simplified to the calculation of the internal force reinforcement of the "work" section. When the vertical pipe direction is used, the calculation of the inner force reinforcement of the cross section of the intermediate plate is stopped. The section of the air shower column is stopped with internal force reinforcement. Calculation. 2, air shower room design common structure request 1) air shower room 普通 grade should generally ≥ C20, board thickness can be generally: 2) air shower room minimum reinforcement rate 0.2% 3) air shower room maximum reinforcement rate 1.2% 4 Air entrainment chamber hollow rate 30% -55% 5) Air shower room bathroom floor landing 80--360mm range 6) Air shower room compliance span ≤ 15 meters (non-prestressed), ≤ 25 meters (prestress) 7) Air shower room structure


Recent viewed:

Contact

|  Hotline

0512-87882886

|  Mobile

13052855196 / 15895661736

Website:www.ksgxq.com
Address:777 Yanwu North Road,Qiandeng Town,Kunshan City


WeChat Official Account
Mobile website